Installation Instructions

The nuts of ROKE hydraulic fittings are all silver plated, and spray nano lubricating layer with our own patent . In this way, the installation torque can be controlled within a reasonable range. Especially in the case of narrow space or suspended operation, it makes installation very easy.

For proper assembly following assembly instruction shall be followed. Improper assembly may lead to malfunctions or impair safety.

Assembly in fitting body

Cut the tube:

1/2˚ angle tolerance to the tube axis is permissible. Tube cutter is not recommendable.

info-318-115

Lightly remove chips and particles from the inside and outside cut edges of tube. Bevel up to 0.2mm × 45˚

is permissible.

For tube bend, the minimum height from the straight pipe end to the bending radius must be at least twice the

height of the nut.

4. Lubricate thread and cone of the fitting body, ring and thread of nut.

info-434-120

Assembly

5. Slip nut and then ring onto the tube end. Ensure that the ring is placed correctly.

6. Screw nut manually onto fitting body until finger tight. Hold the tube against the shoulder in the cone of the fitting body.

7. Mark nut and tube for measuring the prescribed turns of the nut.

8. Tighten the nut 1 1/4 turns. Tube must not turn with tube. Stop edge of the ring limits over-tightening by increasing tightening torque.

info-967-232

Check & Final Assembly

9. Loosen nut and remove ring-mounted tube from fitting. And check if a visivle collar has formed on the pipe in front of the first cutting edge. If not, tighten slightly more.

10. Insert the pre-assembled tube into the fitting.

While holding fitting body with a wrench, tighten nut approx. 1/4 revolution beyond the point of a clearly perceptible resistance.